A 3/4 view of a Retego Certus COR case. It is a hardened bright orange field case with identifying labels.

Retego Certus™ COR

Carbon steel and copper can corrode in any situation. Find out why.

Ferrous iron, ferric iron, sulfide, and the full suite of corrosion indices, measured on-site in 1-24 hours. Built for integrity engineers, corrosion specialists, and chemical treatment programs that need a same-day decision.

All the specs.

Corrosion is never one thing.

Corrosion is rarely caused by a single agent. In real-world systems, it is the interaction between iron speciation, sulfide presence, dissolved oxygen, scale-forming minerals, and water chemistry stability that determines whether a pipe survives or fails. Retego Certus COR measures the full panel of corrosion-relevant parameters and applies industry-standard predictive indices to give an integrity engineer or chemical treatment professional the complete picture in a single visit.

The result is a field-deployable diagnostic suite that can answer the real corrosion question at the wellsite, in the plant, or at the customer's facility. Not, “Is there corrosion?” but “What kind? How aggressive? What treatment?”

Contents of a Retego Certus COR case laid out in a grid pattern. Featuring the hardened field case, sterile transfer pipettes, disposable gloves, cuvette holder, instruction manual, and COR cuvettes.

Contents

  • Field Case with Tray
  • Sterile Transfer Pipettes
  • Disposable Gloves
  • Carbon Steel Sample Vial
  • Copper Sample Vial
  • Carbon Steel Control Cuvette
  • Copper Control Cuvette
  • Test Instructions
  • Carbon Steel Sample Cuvettes
  • Copper Sample Cuvettes
Click here to watch a video on how to conduct the Certus COR test

Use cases

Refinery Cooling Water Programs

A refinery cooling water program runs the full corrosion panel weekly at multiple sample points. The scaling and stability indices drive a real-time adjustment to chemical treatment instead of a monthly retrospective.

Midstream Pipeline integrity

A pipeline integrity engineer pairs Retego Certus COR with Retego Certus SRB at each pig receiver. Receive same-day data on both chemical and microbial corrosion drivers. Treatment programs adjust on the field engineer's next call.

Commercial Boiler Diagnostics

A commercial mechanical contractor diagnoses a boiler scaling problem on-site in a single visit. Langelier and Puckorius indices identify aggressive water; the treatment recommendation is written before the customer signs the visit ticket.

MethodTime to full panelParameters in one workflowPredictive indices included
Retego Certus™ COR1–24 hoursIron speciation + sulfide + indicesYes
Single-parameter stripsSequential, slowOne per stripNo
Send-out lab analysis5 to 7 daysVariable by requestSometimes

FAQ

Does the kit measure both ferrous and ferric iron?
Can it be used on residential samples?
Is dissolved oxygen included?